Manufacturer Approval Code / Product Approval Code |
2213 / 07-667 | ||||||||
Types |
|
||||||||
Size |
|
||||||||
Weight | KYK PEARL 6 kg; KYK 25000 6 kg; KYK 30000 7 kg; KYK GEN II 8 kg; | ||||||||
Installation | Standing or wall-mounted Direct connection to tap or undersink connection |
||||||||
LCD Display | Displays pH and ORP levels (7 colors), water flow rate per minute, self-clean, sound indicator, filter life for 1st filter and 2nd filter, auto-diagnosis codes | ||||||||
Controlling Method | Touch Sensor | ||||||||
pH Range | Adjustable from 3.8 to 10.2 pH Preset levels: 4.0 / 4.5 / 5.0 / 5.5 / 7.0 / 8.5 / 9.0 / 9.5 / 10.0 |
||||||||
ORP Range | Adjustable from +790 to -460 | ||||||||
Electrolysis | Electrolysis Method | Continuous electrolysis with a flow sensor | |||||||
Electrolysis Ability | 4 preset levels of alkaline water, 4 preset levels of acidic water, one preset level of neutral pH filtered water | ||||||||
Electrolysis Capacity |
|
||||||||
Electrolysis Cell |
|
||||||||
Electrolysis Power |
|
||||||||
Electrode Sheet Wash | Automatic washing (controlled by mycom) | ||||||||
Filter | Filter Life Estimate | KYK PEARL Single Filter: can handle up to 3,500 litresKYK 25000 / 30000 / KYK GEN II 1st Filter: can handle up to 6,000 litres 2nd Filter: can handle up to 9,000 litres |
|||||||
Filtering Material (Made in Korea) |
1st filter/single filter: Antibacteria filter, Zeomic, Noxious Odor Calcium, Active Carbon (with silver added), Sediment filter 2nd filter: Antibacteria filter, Granular Activated Carbon, Active Carbon (with silver added) |
||||||||
Message to indicate Filter Change | Alert message on LCD screen when filter life indicator reaches 70L. If the taste and smell of water is not normal, you should change the filter anyway | ||||||||
Available Temperature | 5˚C ~ 30˚C or 41˚F ~ 86˚F | ||||||||
Available Water Pressure | 1.5 ~ 3.0 kgf/cm2 | ||||||||
Power Source Protector | Glass Tube Fuse | ||||||||
Over-current Detector | Automatically stops the output of electrolytic cells | ||||||||
Over-Temperature Protector | The temperature detector circuit installed inside the SMPS automatically stops the device |